Тех. данные
Опции
Order No. supplements
Motor type
|
Penultimate position: Voltage code
|
Final position: Type of construction code
|
|
50 Hz
|
Without flange
|
With flange
|
With standard
flange
|
With special flange
|
|
230 VΔ/400 VY
|
400 VΔ/690 VY
|
500 VY
|
500 VΔ
|
IM B3/6/7/8, IM V6,
IM V5 without protective cover 1)
|
IM B5, IM V1 without protective cover
IM V3 2)3)
|
IM V1 without protective cover 4)
|
IM V1 with protective cover 2)4)
|
IM B35
|
IM B14, IM V19, IM V18 without protective cover
|
IM B34
|
IM B14, IM V19, IM V18 without protective cover
|
|
1
|
6
|
3
|
5
|
0
|
1
|
8
|
4
|
6
|
2
|
7
|
3
|
1LG6 18 . ‑ . . . ❑❑
|
☺
|
☺
|
☺
|
☺
|
❑
|
✓
|
–
|
✓
|
✓
|
–
|
–
|
–
|
1LG6 20 . ‑ . . . ❑❑
|
☺
|
☺
|
☺
|
☺
|
❑
|
✓
|
–
|
✓
|
✓
|
–
|
–
|
–
|
1LG6 22 . ‑ . . . ❑❑
|
☺
|
☺
|
☺
|
☺
|
❑
|
✓
|
–
|
✓
|
✓
|
–
|
–
|
–
|
1LG6 25 . ‑ . . . ❑❑
|
☺
|
☺
|
☺
|
☺
|
❑
|
✓
|
–
|
✓
|
✓
|
–
|
–
|
–
|
1LG6 28 . ‑ . . . ❑❑
|
☺
|
☺
|
☺
|
☺
|
❑
|
✓
|
–
|
✓
|
✓
|
–
|
–
|
–
|
1LG6 310 ‑ . . . ❑❑
1LG6 313 ‑ . . . ❑❑
|
☺
|
☺
|
☺
|
☺
|
❑
|
✓
|
–
|
✓
|
✓
|
–
|
–
|
–
|
1LG6 316 ‑ . . . ❑❑
1LG6 317 ‑ . . . ❑❑
1LG6 318 ‑ . . . ❑❑
|
–
|
☺
|
–
|
☺
|
❑5)
|
–
|
✓6)
|
✓6)
|
✓
|
–
|
–
|
–
|
❑ Standard version
☺ Without additional charge
✓ With additional charge
– Not possible
Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see “Special versions” in the “Selection and ordering data” under “Voltages”).
Order other types of construction with type of construction code 9 in the final position and the corresponding order code (see “Special versions” in the “Selection and ordering data” under “Types of construction”).
1) If motors 1LG6 183-... to 1LG6 318-... (motor series 1LG6 frame sizes 180 M to 315 L) in types of construction with feet IM B6, IM B7, IM V6 or IM V5 without protective cover are fixed to the wall, it is recommended that the motor feet are supported.
2) 1LG6 220-... to 1LG6 318-... motors (motor series 1LG6 frame sizes 225 S to 315 L) are supplied with two screwed-in eyebolts in accordance with IM B5, whereby one can be moved in accordance with IM V1 or IM V3. It is important to note that stress must not be applied perpendicular to the ring plane.
3) Type of construction IM V3 is only possible using type of construction code 9 and order code M1G.
4) The “Second shaft extension” option, order code K16 is not possible.
5) Type of construction IM V6 and IM V5 without protective cover is only possible using type of construction code 9 and order code M1E or M1D.
6) 2-pole motors in 60 Hz version available on request.