Тех. данные
Опции
Special versions according to ATEX
Motor type
|
Zone 2
|
|
VIK (includes Zone 2) 1)
|
Zone 21
|
|
Zone 22
|
|
|
|
Mains-fed operation
|
Converter-fed operation (FC)
|
Mains-fed operation
|
Converter-fed operation (FC)
|
Mains-fed operation
|
Converter-fed operation (FC)
|
Mains-fed operation
|
Converter-fed operation (FC)
|
|
Frame size
|
Order code
M72
|
Order code M73
|
Order code K30
|
On request
|
Order code M34
|
Order code M38
|
Order code M35
|
Order code M39
|
1LA9
|
56
|
–
|
–
|
–
|
–
|
✓
|
✓
|
✓
|
✓
|
63
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
71
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
80
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
90
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
100
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
112
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
132
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
160
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
180
|
–
|
–
|
–
|
–
|
✓
|
✓
|
✓
|
✓
|
200
|
–
|
–
|
–
|
–
|
✓
|
✓
|
✓
|
✓
|
✓ With additional charge
– Not possible
1) If the marking Ex nA II is required in addition to VIK on the rating plate, this must be ordered using order code C27. The VIK version is not possible in combination with Zones 21 and 22.
Order No. supplements
Motor type
|
Penultimate position: Voltage code
|
Final position: Type of construction code
|
|
60 Hz
|
|
Without flange
|
With flange
|
With standard flange
|
With special flange
|
|
460 VY
|
460 VΔ
|
IM B3/6/7/8, IM V6 1)
|
IM B5, IM V3 1)
|
IM V1 with protective cover 1)2)
|
IM B35
|
IM B14, IM V19 1)
|
IM B34
|
IM B14, IM V19 1)
|
|
(see "Introduction"
for outputs at 60 Hz)
|
|
1
|
6
|
0
|
1
|
4
|
6
|
2
|
7
|
3
|
1LA9 05 . ‑ . . . ❑❑
|
☺
|
☺
|
❑
|
✓
|
–
|
–
|
✓
|
✓
|
✓
|
1LA9 06 . ‑ . . . ❑❑
|
☺
|
☺
|
❑
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
1LA9 07 . ‑ . . . ❑❑
|
☺
|
☺
|
❑
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
1LA9 08 . ‑ . . . ❑❑
|
☺
|
☺
|
❑
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
1LA9 09 . ‑ . . . ❑❑
|
☺
|
☺
|
❑
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
1LA9 10 . ‑ . . . ❑❑
|
☺
|
☺
|
❑
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
1LA9 11 . ‑ . . . ❑❑
|
☺
|
☺
|
❑
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
1LA9 13 . ‑ . . . ❑❑
|
☺
|
☺
|
❑
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
1LA9 16 . ‑ . . . ❑❑
|
☺
|
☺
|
❑
|
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
1LA9 18 . ‑ . . . ❑❑
|
☺
|
☺
|
❑
|
✓ 3)
|
✓
|
✓
|
–
|
–
|
–
|
1LA9 20 . ‑ . . . ❑❑
|
☺
|
☺
|
❑
|
✓ 3)
|
✓
|
✓
|
–
|
–
|
–
|
❑ Standard version
☺ Without additional charge
✓ With additional charge
– Not possible
Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see "Special versions" in the "Selection and ordering data" under "Voltages").
Order other types of construction with type of construction code 9 in the final position and the corresponding order code (see "Special versions" in the "Selection and ordering data" under "Types of construction").
1) The following applies for explosion-proof motors: In the case of the types of construction with shaft end down, the version "with protective cover" is required. For types of construction with shaft extension pointing upwards, a suitable cover must be implemented to prevent small parts from falling into the fan cover (see the standard IEC/EN 60079-0). The cover must not block the cooling air-flow.
2) The "Second shaft extension" option, order code K16 is not possible.
3) Type of construction IM V3 is only possible using type of construction code 9 and order code M1G.