Обзор
Обзор
1FS6 explosion-protected synchronous servomotors
1FS6 motors are permanent-magnet synchronous motors for use in Zone 1 hazardous areas.
They are designed in compliance with the EEx de IIC T3 type of protection, certified according to ATEX guidelines 94/9/EG, and also have CSA approval for Class 1, Zone 1, Temperature Class T3 (CAN/CSA-79-1-95 "Flameproof enclosure").
In addition to compliance with the ATEX guidelines, the motors also comply with the applicable standards and regulations for hazardous environments:
- IEC EN 60079-0
General Conditions for Electrical Equipment for Potentially Explosive Atmospheres
- IEC EN 60079-1
Standard referring to EEx d type of protection
- IEC EN 60079-7
Standard referring to EEx e type of protection
- IEC EN 60079-15
Standard referring to Ex nA type of protection
1FS6 motors can be combined with the SINAMICS S120 drive system to create a powerful, high-performance system. The integrated encoder systems for speed and position control can be selected depending on the application.
The motors are designed for operation without external cooling as the heat is dissipated through the motor surface.
Область применения
1FS6 motors with explosion protection are suitable for operation in Zone 1 hazardous areas in any industrial sector or machine type, including, for example, in
- Flexographic printing and platen-printing machines
- Filling plants with potentially explosive vapors
- Film coating plants
Заказные данные
Заказной № |
Вес, кг |
Описание |
Наличие на складе |
Заказать |
1FS6074-6AC71-.... |
29 |
Ex-серводвигатель 7, 2нм 1, 5 квт; 2000 об/мин; 6-пол. im b5 (im v1, im v3) естественная вентиляция |
------ |
|
1FS6074-6AF71-.... |
29 |
Ex-серводвигатель 6, 3нм 2, 0 квт; 3000 об/мин; 6-пол. im b5 (im v1, im v3) естественная вентиляция |
------ |
|
1FS6074-6AH71-.... |
29 |
Ex-серводвигатель 4, 5нм 2, 1 квт; 4500 об/мин; 6-пол. im b5 (im v1, im v3) естественная вентиляция |
------ |
|
1FS6074-6AK71-.... |
29 |
Ex-серводвигатель 1, 9 нм 1, 2 квт; 6000 об/мин; 6-пол. im b5 (im v1, im v3) естественная вентиляция |
------ |
|
1FS6096-8AC71-.... |
55 |
Ex-серводвигатель 20нм 4, 2 квт; 2000 об/мин; 8-пол. im b5 (im v1, im v3) естественная вентиляция |
------ |
|
1FS6096-8AF71-.... |
55 |
Ex-серводвигатель 17нм 5, 3 квт; 3000 об/мин; 8-пол. im b5 (im v1, im v3) естественная вентиляция |
------ |
|
1FS6096-8AH71-.... |
55 |
Ex-серводвигатель 11нм 5, 2 квт; 4500 об/мин; 8-пол. im b5 (im v1, im v3) естественная вентиляция |
------ |
|
1FS6115-8AB73-.... |
87 |
Ex-серводвигатель 37нм 5, 8 квт; 1500 об/мин; 8-пол. im b35 (im v15, im v36) естественная вентиляция |
------ |
|
1FS6115-8AC73-.... |
87 |
Ex-серводвигатель 34нм 7, 1 квт; 2000 об/мин; 8-пол. im b35 (im v15, im v36) естественная вентиляция |
------ |
|
1FS6115-8AF73-.... |
87 |
Ex-серводвигатель 28нм 8, 8 квт; 3000 об/мин; 8-пол. im b35 (im v15, im v36) естественная вентиляция |
------ |
|
1FS6134-6AB73-.... |
119 |
Ex-серводвигатель 68нм 10, 7 квт; 1500 об/мин; 6-пол. im b35 (im v15, im v36) естественная вентиляция |
------ |
|
1FS6134-6AC73-.... |
119 |
Ex-серводвигатель 59нм 12, 4 квт; 2000 об/мин; 6-пол. im b35 (im v15, im v36) естественная вентиляция |
------ |
|
Тех. данные
Особенности
- Winding insulation for temperature class 180 (H)
- High cantilever load
- Naturally cooled motors with terminal box for power connection
- Additional terminal box for connection of encoder system and temperature sensors
- Monitoring of motor temperature with KTY 84-130 and PTC thermistor (triggering device must be certified according to test mark PTB 3x PTC-01 ATEX 3218, e.g. SIMIREL 3RN10 thermistor motor protection)

Дополнительную информацию вы можете получить загрузив
файл в формате PDF (76085 байт).
Технические данные
Type of motor
|
AC servomotor
(permanent-magnet synchronous motor)
|
Magnet material
|
Rare-earth magnet material
|
Insulation of the stator winding in accordance with EN 60034‑1 (IEC 60034‑1)
|
Thermal Class 180 H for a winding temperature rise of ΔT = 100 K at an ambient temperature of 40 °C (104 °F)
|
Cooling
|
Natural cooling
|
Temperature monitoring
|
3 PTC thermistors + KTY 84 temperature sensor
in stator winding
|
Type of construction in accordance with EN 60034‑7 (IEC 60034‑7)
|
|
|
IM B5
|
|
IM B35
|
Schutzart nach EN 60034‑5 (IEC 60034‑5)
|
IP64
|
Shaft extensionon the drive end in accordance with DIN 748‑3 (IEC 60072‑1)
|
Plain shaft
|
Shaft and flange accuracy in accordance with DIN 42955 (IEC 60072‑1)1)
|
Tolerance N (normal)
|
Vibration magnitude in accordance with EN 60034‑14 (IEC 60034‑14)
|
Grade N (normal)
|
Bearings
|
Permanently lubricated deep-groove ball bearings
|
Built-in encoder systems
|
- Incremental encoder sin/cos 1 Vpp 2048 S/R
- Absolute encoder EnDat 2048 S/R1)
|
Connection
|
2 terminal boxes
|
Paint finish
|
Anthracite RAL 7016
|
Options
|
- Shaft extension with fitted key and keyway
(half-key balancing)
- Shaft and flange accuracy
Tolerance R
- IP65 degree of protection with radial shaft seal
|
S/R = signals/revolution
1) Shaft extension run-out, concentricity of centering ring and shaft, and perpendicularity of flange to shaft.
2) If the absolute encoder is used, Mrated is reduced by 10 %.
Notice
A PTC thermistor triggering device, such as SIMIREL 3RN10 thermistor motor protection, is mandatory for operating these machines in potentially explosive environments. The connection cables must be able to withstand temperatures of at least +100 °C (+212 °F).
The motors can be connected to SINAMICS S120 drive system only by way of a terminal box. It is not permissible to use connector plugs in Zone 1 areas. Encoders must be connected by means of an SMC20 Sensor Module Cabinet-Mounted.
Характеристика
|
|