Заказной № |
Вес, кг |
Описание |
Наличие на складе |
Заказать |
6SE0383-1BJ36-3AA6 |
1520 |
DYNAVERT I 2J3A-86950-800 current-source DC link converter 950 V 3 AC 1035 kVA 6/6-pulse Typical motor output 800 kW I-duration 630 A short-time 695 A H*W*D=2002*2406*605 mm IP21 air-cooled |
------ |
|
6SE0383-1BJ37-0AA6 |
1550 |
DYNAVERT I 2J3A-86950-900 current-source DC link converter 950 V 3 AC 1150 kVA 6/6-pulse Typical motor output 900 kW I-duration 700 A short-time 770 A H*W*D=2002*2406*605 mm IP21 air-cooled |
------ |
|
6SE0383-1BJ37-8AA6 |
2290 |
DYNAVERT I 2J3A-86950-910 current-source DC link converter 950 V 3 AC 1300 kVA 6/6-pulse Typical motor output 1000 kW I-duration 790 A short-time 870 A H*W*D=2002*3206*605 mm IP21 air-cooled |
------ |
|
6SE0383-1BJ38-4AA6 |
2385 |
DYNAVERT I 2J3A-86950-911 current-source DC link converter 950 V 3 AC 1380 kVA 6/6-pulse Typical motor output 1100 kW I-duration 840 A short-time 925 A H*W*D=2002*3206*605 mm IP21 air-cooled |
------ |
|
6SE0383-1BJ38-8AA6 |
2495 |
DYNAVERT I 2J3A-86950-912 current-source DC link converter 950 V 3 AC 1580 kVA 6/6-pulse Typical motor output 1200 kW I-duration 960 A short-time 1055 A H*W*D=2002*3206*605 mm IP21 air-cooled |
------ |
|
6SE0383-1BJ41-1AA6 |
2585 |
DYNAVERT I 2J3A-86950-915 current-source DC link converter 950 V 3 AC 1940 kVA 6/6-pulse Typical motor output 1500 kW I-duration 1180 A short-time 1300 A H*W*D=2002*3206*605 mm IP21 air-cooled |
------ |
|
6SE0383-2CC32-7AA6 |
1670 |
DYNAVERT I 2J3F-86690-220 current-source DC link converter 690 V 6 AC 320 kVA 12/6-pulse Typical motor output 220 kW I-duration 270 A short-time 297 A H*W*D=2202*1206*605 mm IP21 air-cooled |
------ |
|
6SE0383-2CC33-1AA6 |
1530 |
DYNAVERT I 2J3F-86690-250 current-source DC link converter 690 V 6 AC 370 kVA 12/6-pulse Typical motor output 250 kW I-duration 310 A short-time 341 A H*W*D=2202*1206*605 mm IP21 air-cooled |
------ |
|
6SE0383-2CC33-5AA6 |
2020 |
DYNAVERT I 2J3F-86690-315 current-source DC link converter 690 V 6 AC 420 kVA 12/6-pulse Typical motor output 315 kW I-duration 350 A short-time 385 A H*W*D=2002*2406*605 mm IP21 air-cooled |
------ |
|
6SE0383-2CC34-3AA6 |
2420 |
DYNAVERT I 2J3F-86690-400 current-source DC link converter 690 V 6 AC 510 kVA 12/6-pulse Typical motor output 400 kW I-duration 430 A short-time 475 A H*W*D=2002*2406*605 mm IP21 air-cooled |
------ |
|
6SE0383-2CC35-5AA6 |
2910 |
DYNAVERT I 2J3F-86690-500 current-source DC link converter 690 V 6 AC 660 kVA 12/6-pulse Typical motor output 500 kW I-duration 550 A short-time 605 A H*W*D=2002*2406*605 mm IP21 air-cooled |
------ |
|
6SE0383-2CC37-0AA6 |
3040 |
DYNAVERT I 2J3F-86690-630 current-source DC link converter 690 V 6 AC 820 kVA 12/6-pulse Typical motor output 630 kW I-duration 690 A short-time 760 A H*W*D=2002*2406*605 mm IP21 air-cooled |
------ |
|
6SE0383-2CC37-8AA6 |
3545 |
DYNAVERT I 2J3F-86690-700 current-source DC link converter 690 V 6 AC 930 kVA 12/6-pulse Typical motor output 700 kW I-duration 780 A short-time 860 A H*W*D=2002*2406*605 mm IP21 air-cooled |
------ |
|
6SE0383-2CC38-4AA6 |
3650 |
DYNAVERT I 2J3F-86690-800 current-source DC link converter 690 V 6 AC 1000 kVA 12/6-pulse Typical motor output 800 kW I-duration 840 A short-time 925 A H*W*D=2002*2806*605 mm IP21 air-cooled |
------ |
|
6SE0383-2CC41-1AA6 |
2290 |
DYNAVERT I 2J3F-86690-910 current-source DC link converter 690 V 6 AC 1310 kVA 12/6-pulse Typical motor output 1000 kW I-duration 1100 A short-time 1210 A H*W*D=2002*3206*605 mm IP21 air-cooled |
------ |
|
6SE0383-2CC41-2AA6 |
2520 |
DYNAVERT I 2J3F-86690-911 current-source DC link converter 690 V 6 AC 1430 kVA 12/6-pulse Typical motor output 1100 kW I-duration 1200 A short-time 1320 A H*W*D=2002*3206*605 mm IP21 air-cooled |
------ |
|
6SE0383-2CC41-3AA6 |
3820 |
DYNAVERT I 2J3F-86690-912 current-source DC link converter 690 V 6 AC 1600 kVA 12/6-pulse Typical motor output 1200 kW I-duration 1340 A short-time 1475 A H*W*D=2002*4806*605 mm IP21 air-cooled |
------ |
|
6SE0383-2CC41-7AA6 |
3970 |
DYNAVERT I 2J3F-86690-916 current-source DC link converter 690 V 6 AC 2080 kVA 12/6-pulse Typical motor output 1600 kW I-duration 1740 A short-time 1915 A H*W*D=2002*4806*605 mm IP21 air-cooled |
------ |
|
6SE0176-1BB37-0AA6 |
850 |
DYNAVERT T 2T6A-75501-500 230-500V 3AC, IT, 50/60 Hz Motor output (typ.) 500kW (500V) 2202*1406*605 mm IP54, water cooled, 6/6-pulse system EMC Directive EN60204-1 Line reactor/du/dt Output filter |
------ |
|
6SE0176-1BB38-2AA6 |
870 |
DYNAVERT T 2T6A-76501-560 230-500V 3AC, IT, 50/60 Hz Motor output (typ.) 560kW (500V) 2202*1806*605 mm IP54, water cooled, 6/6-pulse system EMC Directive EN60204-1 Line reactor/du/dt Output filter |
------ |
|
6SE0176-1BB38-8AA6 |
920 |
DYNAVERT T 2T6A-76501-630 230-500V 3AC, IT, 50/60 Hz Motor output (typ.) 630kW (500V) 2202*1806*605 mm IP54, Water cooled, 6/6-pulse system EMC Directive EN60204-1 Line reactor/du/dt Output filter |
------ |
|
6SE0176-1BB41-0AA6 |
910 |
DYNAVERT T 2T6A-76501-710 230-500V 3AC, IT, 50/60 Hz Motor output (typ.) 710kW (500V) 2202*1806*605 mm IP54, Water cooled, 6/6-pulse system EMC Directive EN60204-1 Line reactor/du/dt Output filter |
------ |
|
6SE0176-1BB41-1AA6 |
1000 |
DYNAVERT T 2T6A-76501-800 230-500V 3AC, IT, 50/60 Hz Motor output (typ.) 800kW (500V) 2202*1806*605 mm IP54, Water cooled, 6/6-pulse system EMC Directive EN60204-1 Line reactor/du/dt Output filter |
------ |
|
6SE0176-1BC33-2AA6 |
460 |
DYNAVERT T 2T6A-75691-250 400-690V IT, OPT. TN/TT, 50/60 Hz Motor output (typ.) 250kW (690V) 2002*806*605 mm IP54, water cooled, 6/6-pulse system EMC Directive EN60204-1 Line reactor/du/dt Output filter |
------ |
|
6SE0176-1BC33-6AA6 |
480 |
DYNAVERT T 2T6A-75691-315 400-690V IT, OPT. TN/TT, 50/60 Hz Motor output (typ.) 315kW (690V) 2002*806*605 mm IP54, water cooled, 6/6-pulse system EMC Directive EN60204-1 Line reactor/du/dt Output filter |
------ |
|