Spare parts generally of the GG LD (GG_LD)

В этой рубрике 2689 кодов.

Страницы: [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] [20] [21] [22] [23] [24] [25] [26] [27] [28] [29] [30] [31] [32] [33] [34] [35] [36] [37] [38] [39] [40] [41] [42] [43] [44] [45] [46] [47] [48] [49] [50] [51] [52] [53] [54] [55] [56] [57] [58] [59] [60] [61] [62] [63] [64] [65] [66] [67] [68] [69] [70] [71] [72] [73] [74] [75] [76] [77] [78] [79] [80] [81] [82] [83] [84] [85] [86] [87] [88] [89] [90] [91] [92] [93] [94] [95] [96] [97] [98] [99] [100] [101] [102] [103] [104] [105] [106] [107] [108]
Заказной № Вес, кг Описание Наличие на складе Заказать
6SE0383-1BB25-0AA6 360 DYNAVERT I 2J3A-86500-030 current-source DC link converter 500 V 3 AC 43 kVA 6/6-pulse Typical motor output 30 kW I-duration 50 A short-time 55 A H*W*D=2002*606*605 mm IP21 air-cooled ------
6SE0383-1BB26-0AA6 380 DYNAVERT I 2J3A-86500-037 current-source DC link converter 500 V 3 AC 52 kVA 6/6-pulse Typical motor output 37 kW I-duration 60 A short-time 66 A H*W*D=2002*606*605 mm IP21 air-cooled ------
6SE0383-1BB27-5AA6 420 DYNAVERT I 2J3A-86500-045 current-source DC link converter 500 V 3 AC 65 kVA 6/6-pulse Typical motor output 45 kW I-duration 75 A short-time 83 A H*W*D=2002*606*605 mm IP21 air-cooled ------
6SE0383-1BB28-8AA6 470 DYNAVERT I 2J3A-86500-055 current-source DC link converter 500 V 3 AC 78 kVA 6/6-pulse Typical motor output 55 kW I-duration 90 A short-time 99 A H*W*D=2002*606*605 mm IP21 air-cooled ------
6SE0383-1BB31-2AA6 520 DYNAVERT I 2J3A-86500-075 current-source DC link converter 500 V 3 AC 105 kVA 6/6-pulse Typical motor output 75 kW I-duration 120 A short-time 132 A H*W*D=2002*606*605 mm IP21 air-cooled ------
6SE0383-1BB31-4AA6 547 DYNAVERT I 2J3A-86500-090 current-source DC link converter 500 V 3 AC 125 kVA 6/6-pulse Typical motor output 90 kW I-duration 145 A short-time 160 A H*W*D=2202*606*605 mm IP21 air-cooled ------
6SE0383-1BB31-8AA6 610 DYNAVERT I 2J3A-86500-110 current-source DC link converter 500 V 3 AC 155 kVA 6/6-pulse Typical motor output 110 kW I-duration 180 A short-time 198 A H*W*D=2202*606*605 mm IP21 air-cooled ------
6SE0383-1BB32-1AA6 900 DYNAVERT I 2J3A-86500-132 current-source DC link converter 500 V 3 AC 185 kVA 6/6-pulse Typical motor output 132 kW I-duration 215 A short-time 237 A H*W*D=2002*1206*605 mm IP21 air-cooled ------
6SE0383-1BB32-4AA6 985 DYNAVERT I 2J3A-86500-160 current-source DC link converter 500 V 3 AC 210 kVA 6/6-pulse Typical motor output 160 kW I-duration 240 A short-time 264 A H*W*D=2002*1206*605 mm IP21 air-cooled ------
6SE0383-1BB32-8AA6 1095 DYNAVERT I 2J3A-86500-200 current-source DC link converter 500 V 3 AC 255 kVA 6/6-pulse Typical motor output 200 kW I-duration 295 A short-time 325 A H*W*D=2002*1206*605 mm IP21 air-cooled ------
6SE0143-1FL00-0AA5 110 Control cabinet Rittal H*W*D= 2000*606*605 mm for installation of compact units with Control ------ Заказать
6SE0143-1KA15-5AA5 137 DYNAVERT T 2x3A-85400-002 230-500V 3AC, TN/TT 50/60 Hz Motor output (typ.) 2.2kW (400V) one inverter in the cabinet HWD= 2000*606*605mm, IP21, direction of cooled, 6/6-pulse system EMC Directive EN60204-1 Line filter class A according to EN55011 Line reactor/du/dt Output filter ------
6SE0143-1KA17-0AA5 137 DYNAVERT T 2x3A-85400-003 230-500V 3AC, TN/TT 50/60 Hz Motor output (typ.) 3kW (400V) one inverter in the cabinet HWD= 2000*606*605mm, IP21, direction of cooled, 6/6-pulse system EMC Directive EN60204-1 Line filter class A according to EN55011 Line reactor/du/dt Output filter ------
6SE0383-2CC42-0AA6 5800 DYNAVERT I 2J3F-86690-918 current-source DC link converter 690 V 6 AC 2290 kVA 12/6-pulse Typical motor output 1800 kW I-duration 1920 A short-time 2110 A H*W*D=2002*3206*1210 mm IP21 air-cooled ------
6SE0383-2CC42-1AA6 5910 DYNAVERT I 2J3F-86690-920 current-source DC link converter 690 V 6 AC 2580 kVA 12/6-pulse Typical motor output 2000 kW I-duration 2160 A short-time 2375 A H*W*D=2002*3206*1210 mm IP21 air-cooled ------
6SE0383-2CC42-3AA6 6460 DYNAVERT I 2J3F-86690-922 current-source DC link converter 690 V 6 AC 2750 kVA 12/6-pulse Typical motor output 2200 kW I-duration 2300 A short-time 2530 A H*W*D=2002*3206*1210 mm IP21 air-cooled ------
6SE0383-2CC42-6AA6 6400 DYNAVERT I 2J3F-86690-925 current-source DC link converter 690 V 6 AC 3200 kVA 12/6-pulse Typical motor output 2500 kW I-duration 2680 A short-time 2950 A H*W*D=2002*3206*1210 mm IP21 air-cooled ------
6SE0383-2CC43-0AA6 6600 DYNAVERT I 2J3F-86690-928 current-source DC link converter 690 V 6 AC 3660 kVA 12/6-pulse Typical motor output 2800 kW I-duration 3060 A short-time 3365 A H*W*D=2002*3206*1210 mm IP21 air-cooled ------
6SE0102-1AA15-5AA5 10 DYNAVERT T 2T2A-05400-002 230-500V 3AC, TN/TT 50/60 Hz Motor output (typ.) 2.2kW (400V) 410*165*320 mm IP20, direction of cooled, 6/6-pulse system EMC Directive EN60204-1 Line filter class A according to EN 55011 Line reactor/du/dt Output filter ------
6SE0102-1AA17-0AA5 10 DYNAVERT T 2T2A-05400-003 230-500V 3AC, TN/TT 50/60 Hz Motor output (typ.) 3kW (400V) 410*165*320 mm IP20, direction of cooled, 6/6-pulse system EMC Directive EN60204-1 Line filter class A according to EN 55011 Line reactor/du/dt Output filter ------
6SE0102-1AA21-0AA5 10 DYNAVERT T 2T2A-05400-004 230-500V 3AC, TN/TT 50/60 Hz Motor output (typ.) 4kW (400V) 410*165*320 mm IP20, direction of cooled, 6/6-pulse system EMC Directive EN60204-1 Line filter class A according to EN 55011 Line reactor/du/dt Output filter ------
6SE0102-1AA21-3AA5 10 DYNAVERT T 2T2A-05400-005 230-500V 3AC, TN/TT 50/60 Hz Motor output (typ.) 5.5kW (400V) 410*165*320 mm IP20, direction of cooled, 6/6-pulse system EMC Directive EN60204-1 Line filter class A according to EN55011 Line reactor/du/dt Output filter ------
6SE0102-1AA21-8AA5 10 DYNAVERT T 2T2A-05400-007 230-500V 3AC, TN/TT 50/60 Hz Motor output (typ.) 7.5kW (400V) 510*165*320 mm IP20, direction of cooled, 6/6-pulse system EMC Directive EN60204-1 Line filter class A according to EN55011 Line reactor/du/dt Output filter ------
6SE0102-1AA22-5AA5 10 DYNAVERT T 2T2A-05400-011 230-500V 3AC, TN/TT 50/60 Hz Motor output (typ.) 11kW (400V) 510*165*320 mm IP20, direction of cooled, 6/6-pulse system EMC Directive EN60204-1 Line filter class A according to EN 55011 Line reactor/du/dt Output filter ------
6SE0102-1AA23-7AA5 10 DYNAVERT T 2T2A-05400-015 230-500V 3AC, TN/TT 50/60 Hz Motor output (typ.) 15kW (400V) 610*225*320 mm IP20, direction of cooled, 6/6-pulse system EMC Directive EN60204-1 Line filter class A according to EN 55011 Line reactor/du/dt Output filter ------